{"id":1,"date":"2022-08-29T14:23:11","date_gmt":"2022-08-29T14:23:11","guid":{"rendered":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/?p=1"},"modified":"2023-01-04T23:16:42","modified_gmt":"2023-01-04T23:16:42","slug":"hello-world","status":"publish","type":"post","link":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/2022\/08\/29\/hello-world\/","title":{"rendered":"Harvesting Rainwater!"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Lessons Learned<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4815-1024x768.jpg\" alt=\"\" class=\"wp-image-42\" width=\"650\" height=\"487\" srcset=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4815-1024x768.jpg 1024w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4815-300x225.jpg 300w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4815-768x576.jpg 768w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4815.jpg 1411w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><figcaption>The Headwater Release Basin.<br> Rainwater from the active system and rooftop catchment is released at the designated &#8220;headwater&#8221; location. <br>(From L-R. Slip valve in open position releases water stored in underground conveyance and if left open roof catched water bypasses the tank to headwater (passive). Also used to evacuate &#8220;wet conveyance. First Flush drain and the tank overflow&#8230; A full tank will immediately deliver to headwater)<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">There are a few terms that should be made clear.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pipe or Conveyance<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Catchment<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Earthwork<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Swells <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">System Types: Wet System versus Dry System<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A <span style=\"text-decoration: underline;\">Dry System<\/span> is called so because no water is left in the conveyance. This system type, if applicable to your needs is the simplest method of harvesting rainwater. It is characterized (usually) short run of pipe from the gutter directly into the container. Most often the container (vessel) is located directly under the downspout but could also travel any distance necessary (above the vessel) emptying into the vessel&#8230;  leaving the conveyance emptied of rainwater. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A <span style=\"text-decoration: underline;\">Wet System <\/span>is called so because the systems conveyance retains rainwater. The retention of rainwater in the conveyance is the result of the pipe (all or part) being located below the height of the tank. This system design is usually the choice for larger properties and is a more labor intensive (relative to Dry Systems) because it usually means trenching and burying pipes. The system method allows for storage tanks to be located great distances from the catchment location. This can be a plus for those who would rather the tank not be seen so readily and near the building. It is also beneficial when there are multiple downspouts to connect.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Disadvantages of the wet system is that extended periods of stagnated water in the conveyance can be the cause of water contamination. Biology collected from the roof can decompose within the pipe and be forced into the vessel leading to the fouling of stored water. Therefore, a wet system designer should include a means to evacuate wet conveyances.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"text-decoration: underline;\">Catchment<\/span> is the term used to identify the area that CATCHES to water&#8230; Commonly a roof. but it could be any surface including the ground.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"text-decoration: underline;\">Passive<\/span> versus <span style=\"text-decoration: underline;\">Active<\/span>. Passive system in it&#8217;s simplest form is management of rainwater on the property in effort to encourage rainwater to stay (or at least linger) on the property by use of earth management techniques which include creating <span style=\"text-decoration: underline;\">Swells<\/span>, retention areas with or without rocks and vegetation. With or without a storage vessel.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4594-768x1024.jpg\" alt=\"\" class=\"wp-image-11\" srcset=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4594-768x1024.jpg 768w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4594-225x300.jpg 225w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/IMG_4594.jpg 1058w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><figcaption>Tank is located roughly 40 feet from the catchment downspout. 4 inch PVC is used to convey rainwater to the vessel (1550 gallon).<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Terms:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Head Pressure<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Differential<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Leaf Separator<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First Flush<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In planning, consider that it is desirable to have a continuous decline in the travel of the pipe to induce the flow of water in a desirable direction to ensure a point exists that the retained volume of water can be evacuated by gravity. There are consideration that are key to accomplishing this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First.<br>Establish a tank location that the top of the tank is decidedly lower than the highest point (If the inbound pipe enters the top of the tank (Recommended) account for the pipe when measuring tank height). Be sure to only reference contiguous pipe (no air gap in the pipe). For example if you are installing a <span style=\"text-decoration: underline;\">Leaf Separator<\/span>, reference the height of the pipe that the LS is installed on and not the output of the gutter. (See Gravity Syphon Principles.) <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"933\" height=\"934\" src=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-edited.jpg\" alt=\"\" class=\"wp-image-58\" srcset=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-edited.jpg 933w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-edited-300x300.jpg 300w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-edited-150x150.jpg 150w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-edited-768x769.jpg 768w\" sizes=\"auto, (max-width: 933px) 100vw, 933px\" \/><figcaption>Notice that the gutter output is said to be 10 feet above the foundation. But because the Leaf Separator is open to the air&#8230; the Head Pressure for the downspout begins 20 inches lower. The output of this conveyance (at the tank) must be lower than this height. If adequate differential is not achieved you will not have successful conveyance of rainwater and may experience flooding at the catchment side of the conveyance. <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The greater the head pressure differential the easier it will be to move (by gravity) the rainwater from the conveyance to the tank. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"text-decoration: underline;\">Distribution<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Relying on gravity to both collect and distribute captured rainwater requires careful consideration. For optimal performance the tank should be higher than the targeted watering locations. If the entire tank is higher you will be able to gravity feed the entire tank volume. Whatever the amount of the tanks volume is at or below the target will remain in the tank due to lack of head pressure. You will also achieve a better GPM flow rate with increased positive differential. <\/p>\n\n\n\n<figure class=\"wp-block-image alignfull size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"709\" src=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-e1662041822627-1024x709.jpg\" alt=\"\" class=\"wp-image-57\" srcset=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-e1662041822627-1024x709.jpg 1024w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-e1662041822627-300x208.jpg 300w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-e1662041822627-768x532.jpg 768w, https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-content\/uploads\/2022\/08\/Water-Harvest-FirstFlush-Tank-e1662041822627.jpg 1465w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption>Gravity Systems rely on differential. The differential creates Head Pressure. Observe that the relative tank height is at or lower than the input source. For the purpose of achieving conveyance&#8230; there is no option four inadequate head pressure. <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Think of it as a too and a bottom or think of it as a snow topped mountain top to the bottom. Source rain\/snow slope\/conveyance\/downspout storage tank\/ lakes<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lessons Learned There are a few terms that should be made clear. Pipe or Conveyance Catchment Earthwork Swells System Types: Wet System versus Dry System A Dry System is called so because no water is left in the conveyance. This <span class=\"excerpt-dots\">&hellip;<\/span> <a class=\"more-link\" href=\"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/2022\/08\/29\/hello-world\/\"><span class=\"more-msg\">Continue reading &rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-1","post","type-post","status-publish","format-standard","hentry","category-rainwaterharvesting"],"_links":{"self":[{"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/posts\/1","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/comments?post=1"}],"version-history":[{"count":12,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/posts\/1\/revisions"}],"predecessor-version":[{"id":81,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/posts\/1\/revisions\/81"}],"wp:attachment":[{"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/media?parent=1"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/categories?post=1"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/homeplacecomputing.biz\/rainwaterharvestingtucson\/wp-json\/wp\/v2\/tags?post=1"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}